Use the following commands to configure a CFM segment.
Some of these commands are optional and, if not configured, the default values are used. Default Values for Delay Measurement for a CFM Segment lists the default values for delay measurement for a CFM segment.
Configuration | Default Values |
---|---|
Transmit interval | 10 seconds |
Window | 60 frames |
Timeout | 50 milliseconds |
Alarm threshold | 10% |
Clear threshold | 95% |
Dot1p priority | 6 |
Default Values for Loss Measurement for a CFM Segment lists the default values for loss measurement for a CFM segment.
Configuration | Default Values |
---|---|
LMM Transmit interval | 90 seconds |
Dot1p priority | 6 |
Window | 1200 frames |
SES threshold | 0.01 |
Consecutive available count | 4 |
Note
The statistics for a particular transmission are preserved until the user triggers the transmission once again or if clear counters cfm segment is triggered from the CLI.