Configuring Software-Controlled Redundant Ports
When provisioning software-controlled redundant ports, configure only
one side of the link as redundant. To enable the software-controlled redundant port feature,
the primary and redundant ports must have identical VLAN (Virtual LAN)
membership.
In
the
following figure only the ports on switch C would be configured as
redundant.
-
To configure a software-controlled redundant port, use the
following command:
configure
ports primaryPort redundant secondaryPort {link [on | off]}
The first port specified is the primary port. The second
port specified is the redundant port.
-
Unconfigure a software-controlled redundant port, use
the following command and enter the primary port(s):
unconfigure
ports port_list redundant
-
To configure the switch for the Smart Redundancy feature,
use the following command:
enable
smartredundancy port_list
-
To disable the Smart Redundancy feature, use the following
command:
disable
smartredundancy port_list