Cloning Switches

ExtremeXOS switches provide a script called clone.py that allows you to clone one switch's setup to another switch in the following scenarios:
The clone.py script copies the following:
  • All content under:
    • /boot
    • /exos
    • /alt/boot
    • /alt/exos
    • (optionally) /usr/local/cfg
  • Specific NVRAM contents:
    • Boot selector
    • CLI banner
    • Failsafe username,password, and action

Limitations

  • Requires ExtremeXOS 22.4 or later.
  • Cloning to a standalone switch using a stacking master as the source does not make the standalone switch a stacking master. The configuration cloned from a stacking master to the standalone switch is ignored by ExtremeXOS.
  • ONIE to non-ONIE or non-ONIE to ONIE cloning cannot be performed.

    Newer ExtremeSwitching series switches (X870, X690, X590) use the Open Network Install Environment (ONIE) bootloader. All other ExtremeSwitching series switches do not use ONIE.

  • Clone application does not connect through VR-USER.
  • Synchronize cannot be done for mixed stacking. All nodes in the stack must be the same platform.
  • If the clone master is started and stopped, the dirty bit is set.

Supported Platforms

Cloning is supported on ExtremeSwitching X450-G2, X460-G2, X670-G2, X440-G2, X870, X620, and X690, X590 series switches.