The following information provides tips on how to verify and troubleshoot your Extended Edge Switching topology.
The following limitations apply when using automation to set up an Extended Edge Switching topology.
Limitation | Workaround |
---|---|
Configured BPEs cannot be moved from one port to another port. Auto-configuration does not re-detect the BPEs. | Do one of the following:
|
Auto-configuration does not reliably work on a port if there is any configuration present on that port (cascade port, LAG, or MLAG configuration). If there is LAG/MLAG/cascade configuration on a port, auto-config may not be able to detect the BPE connected to the port. |
|
To verify and troubleshooting the MLAG setup, use the following commands:
show mlag peer {peer_name}—shows if MLAG peer is up.
show configuration {module-name} {detail} with vsm as the module-name—shows MLAG port configuration.
The following limitations apply when using automation to set up redundant CBs.
Limitation | Workaround |
---|---|
If the CB has MLAG peer configuration, but its MLAG peer is down, you cannot enable auto-configuration. |
|
If a BPE is configured before MLAG peer is configured, auto-configuration does not configure the MLAG port for the previously configured BPE. | Manually configure MLAG port for the previously configured BPE by setting the MLAG port ID to 5000 plus the BPE‘s slot number. |