configure cfm domain add association string

configure cfm domain domain_name add association string name [vlan vlan_name|vman vman_name]

Description

Creates a maintenance association (MA) related to a specified maintenance domain (MD). This command supports the character string MA format.

Syntax Description

domain_name

Specifies the domain you want to associate with this MA.

string

Enter up to 45 alphanumeric characters to name the MA.

vlan_name

Specifies the VLAN (Virtual LAN) you want to assign to this MA. Each MA contains only one VLAN, VMAN, or BVLAN.

vman_name

Specifies the VMAN you want to assign to this MA.

Default

N/A.

Usage Guidelines

All ports configured on the specified VLAN are now CFM ports in the specified MA.

You add the MA, or association, to the domain, and the MA uses the MD level assigned to the domain. Each MA can belong to only one domain, but several MAs can belong to a given domain. The MA is unique within a given domain.

Example

The following command creates an MA named service that associates the MD spain and the VLAN finance:

configure cfm domain service add association string spain vlan finance

History

This command was first available in ExtremeXOS 11.4.

The SVLAN option was added in ExtremeXOS 12.4.

Platform Availability

This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X620, X690, X870 series switches.