Enables the automatic entry of subVLAN information in the proxy ARP table.
vlan-name | Specifies a superVLAN name. |
all | Specifies all VLANs. |
Enabled.
To facilitate communication between subVLANs, by default, an entry is made in the IP ARP table of the superVLAN that performs a proxy ARP function. This allows clients on one subVLAN to communicate with clients on another subVLAN. In certain circumstances, intra-subVLAN communication may not be desired for isolation reasons.
Note
The isolation option works for normal, dynamic, ARP-based client communication.The following example enables the automatic entry of subVLAN information in the proxy ARP table of the superVLAN "vsuper":
enable subvlan-proxy-arp vlan vsuper
This command was first available in ExtremeXOS 12.1.
This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X620, X690, X870 series switches.