Shows high-level information for the hardware_vtep schema.
schema | OVSDB schema. |
hardware_vtep | Hardware VXLAN tunnel end-point (VTEP). |
N/A.
The following example shows high-level information for the hardware_vtep schema:
# show ovsdb schema hardware_vtep OVSDB server ============ Enabled : : yes SSL certificate : present hardware_vtep schema ==================== Control Layer enabled : yes Data Forwarding enabled : yes LBS update interval : 60 seconds Configured connections : 1 IP address Port Type Schema --------------- ----- ------------ ---------------- 10.68.6.191 6632 SSL - client hardware_vtep Manager Table connections : 1 Target State Time Count Flags -------------------------- ---------- ------------------- ----- ----- ssl:10.68.6.191:6632 active 2016-10-10 09:17:08 1 Uu Flags: (A) Server has active connections, (d) Most recent disconnect time (D) Client connection is down, (s) Connect and disconnect time are same (u) Most recent connect time, (U) Client connection is up (Z) Server has no connections
This command was first available in ExtremeXOS 22.1.
This command is supported on the Summit X770, X670-G2, and ExtremeSwiching X870, X690 series switches, and stacks with X770, X670-G2, X870, and X690 slots only.