disable cfm segment frame-loss measurement mep

This stops the transmission for both continuous and on-demand mode.

disable cfm segment frame-loss measurement segment_name mep mep_id

Description

This command stops the transmission of the LMM frames for a particular cfm segment.

Syntax Description

segment_name

An alpha numeric string identifying the segment name.

Default

N/A.

Usage Guidelines

This below command stops the transmission of the LMM frames for a particular cfm segment. This stops the transmission for both continuous and on-demand mode.

Example

disable cfm segment cs2 frame-loss measurement mep 3

History

This command was first available in ExtremeXOS 15.1.

Platform Availability

This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X620, X690, X870 series switches.