Note
The AP's LED turns to Blue after the Imagotag server has successfully recognized and established connection with the ESL communicator.server [hostname|ip-address]
server [hostname <HOSTNAME>|ip-address [<IP>|<HOST-ALIAS-NAME>]] {port <1-65535>}
server [hostname <HOSTNAME>|ip-address [<IP>|<HOST-ALIAS-NAME>]] {port <1-65535>}
server | Configures the Imagotag server‘s hostname or IP address |
hostname <HOSTNAME> | Use this option to configure the server‘s hostname.
|
ip-address [<IP>|<HOST-ALIAS-NAME>] | Use this option to configure the ESL server‘s IP address
|
port <1-65535> | Optional. Configures the port on which the ESL server can be
reached.
|
LED Color | Indicates |
---|---|
Red | ESL communicator is up and running on 802.3at, PoE+ mode |
Amber |
ESL communicator is successfully enabled. After the Imagotag policy is applied, the AP's LED color should change to 'Amber' indicating that the ESL communicator is enabled. If it does not turn to Amber, re-check the policy configuration. |
Blue |
Imagotag server has successfully identified the ESL communicator. If the LED color does not turn to 'Blue', check server reachability and confirm the AP-ID configured on the server is correct. For information on configuring AP-ID on server, refer to the Imagotag server configuration guide. |
NOC-NX9500(config-iot-device-type-imagotag-policy-test)#server ip-address 10.234.160.225
NOC-NX9500(config-iot-device-type-imagotag-policy-test)#show context iot-device-type-imagotag-policy test enable output-power Level-B window-size 12 payload-size 25 ssl fcc-mode channel 9 server ip-address 10.234.160.225 NOC-NX9500(config-iot-device-type-imagotag-policy-test)#
no (iot-device-type-imagotag-policy) | Removes the ESL server‘s hostname or IP address configuration |