output-power (iot-device-type-imagotag-policy)

Configures the maximum output power for the ESL communicator

Supported in the following platforms:

Syntax

output-power [Level-A|Level-B|Level-C|Level-D|Level-E|Level-F|Level-G|Level-H]

Parameters

output-power [Level-A|Level-B|Level-C|Level-D|Level-E|Level-F|Level-G|Level-H]
output-power [Level-A|Level-B|Level-C|Level-D|Level-E|Level-F|Level-G|Level-H] Configure the ESL communicator‘s output power in dBm. The options are:
  • Level-A – 1 dBm. This is the default setting.
  • Level-B - -4 dBm
  • Level-C - -6 dBm
  • Level-D - -12 dBm
  • Level-E - 0 dBm
  • Level-F - -2 dBm
  • Level-G - -8 dBm
  • Level-H - -10 dBm
Note: SES-Imagotags recommends NOT to change the default setting, which is in conformance to various country/region specific RF regulations.

Examples

nx9500-6C8809(config-iot-device-type-imagotag-policy-ImagoTagPolicy)#output-power Level-B
nx9500-6C8809(config-iot-device-type-imagotag-policy-ImagoTagPolicy)#show context
 iot-device-type-imagotag-policy ImagoTagPolicy
  enable
  output-power Level-B
  fcc-enable
  channel 9
nx9500-6C8809(config-iot-device-type-imagotag-policy-ImagoTagPolicy)#

Related Commands

no (iot-device-type-imagotag-policy) Reverts the ESL communicator‘s output-power to default (Level-A)