led-timeout

Profile Config Commands

Configures the LED-timeout timer in the device or profile configuration mode

Supported in the following platforms:

  • Access Points — AP505i, AP510i/e, AP560i/h
  • Service Platforms — NX5500, NX7500, NX9500, NX9600, VX9000

Syntax

led-timeout [<15-1440>|shutdown]

Parameters

led-timeout [<15-1440>|shutdown]
led-time [<15-1440>| shutdown] Sets the LED-timeout timer. The value provided here determines the interval (time to lapse) for which a device‘s LEDs are turned off after the last radio state change. For example, if set at 15 minutes, the LEDs are turned off for 15 minutes after the last radio state change.
  • <15-1440> – Specify a value from 15 - 1400 minutes. The default is 30 minutes.
  • shutdown – Shuts down the LED-timeout timer. The device LEDs are not turned off.

Example

nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#led-timeout 25

nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#show context
nx9000 B4-C7-99-6C-88-09
 use profile default-nx9000
 use rf-domain default
 hostname nx9500-6C8809
 license AAP 66069c24b3bb1259b34ff016c723a9e299dd408f0ff891e7c5f7e279a382648397d6b3e975e356a1
 license HTANLT 66069c24b3bb1259eb36826cab3cc83999dd408f0ff891e74b62b2d3594f0b3dde7967f30e49e497
 no autogen-uniqueid
 ip default-gateway 192.168.13.2
 led-timeout 25
 --More--
nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#

nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#led-timeout shutdown

nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#show context
nx9000 B4-C7-99-6C-88-09
 use profile default-nx9000
 use rf-domain default
 hostname nx9500-6C8809
 license AAP 66069c24b3bb1259b34ff016c723a9e299dd408f0ff891e7c5f7e279a382648397d6b3e975e356a1
 license HTANLT 66069c24b3bb1259eb36826cab3cc83999dd408f0ff891e74b62b2d3594f0b3dde7967f30e49e497
 no autogen-uniqueid
 ip default-gateway 192.168.13.2
 led-timeout shutdown
 crypto ikev2 peer IKEv2Peer1
--More--
nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#

Related Commands

no Disables LED-timeout timer