post-authentication-vlan

Configures the VLAN that is assigned to this captive portal‘s users upon successful authentication

Supported in the following platforms:

  • Access Points — AP505i, AP510i/e, AP560i/h
  • Service Platforms — NX5500, NX7500, NX9500, NX9600, VX9000

Syntax

post-authentication-vlan [<1-4096>|<VLAN-ALIAS>]

Parameters

post-authentication-vlan [<1-4096>|<VLAN-ALIAS>]

post-authentication-vlan [<1-4096>|<VLAN-ALIAS>]

Configures the post authentication VLAN. The VLAN specified here is assigned to this captive portal‘s users after they have authenticated and logged on to the network. Provide the VLAN ID, or use an existing VLAN alias to identify the post authentication VLAN.

  • <1-4096> – Specify the VLAN's number from 1 - 4096.

  • <VLAN-ALIAS> – Specify the VLAN alias (should be existing and configured). VLAN alias names begin with a ‘$‘.

Example

rfs4000-229D58(config-captive-portal-test)#post-authentication-vlan 1
rfs4000-229D58(config-captive-portal-test)#show context
captive-portal test
 post-authentication-vlan 1
rfs4000-229D58(config-captive-portal-test)#

Related Commands

no

Removes the post authentication RADIUS VLAN assigned to this captive portal's users