Flood Control is only supported on port-type 0. Three reference limiters are supported. Use the show cos port-type flood-ctrl command to display the port types and their associated ports.

The following example displays default values for the show cos port-type flood-crtl command S-Series output (S-, K-Series):

System(rw)->show cos port-type flood-ctrl
Number of resources:             Supported rate types:
 txq = transmit queue(s)          perc  = percentage
 irl = inbound rate limiter(s)    pps   = packets per second
 orl = outbound rate limiter(s)   Kbps  = kilobits per second
 fld = flood rate limiter(s)      Mbps  = megabits per second
                                  Gbps  = gigabits per second
                                  Tbps  = terabits per second
       Port type     Number of  Supported  Eligible           Unselected
Index  description   limiters   rate type  ports              ports
-----  ------------  ---------  ---------  -----------------  -----------------
0      S-Series         3 fld   perc       ge.4.1-48;         ge.4.1-48;
       Flood Ctrl               pps        ge.6.1-48;         ge.6.1-48;
                                Kbps       ge.8.1-48;         ge.8.1-48;
                                Mbps       ge.8.101-112       ge.8.101-112
                                Gbps

The following example displays default values for the show cos port-type flood-crtl command 7100-Series output (7100-Series):

System(rw)->show cos port-type flood-ctrl
Number of resources:             Supported rate types:
 txq = transmit queue(s)          perc  = percentage
 irl = inbound rate limiter(s)    pps   = packets per second
 orl = outbound rate limiter(s)   Kbps  = kilobits per second
 fld = flood rate limiter(s)      Mbps  = megabits per second
                                  Gbps  = gigabits per second
                                  Tbps  = terabits per second
       Port type     Number of  Supported  Eligible           Unselected
Index  description   limiters   rate type  ports              ports
-----  ------------  ---------  ---------  -----------------  -----------------
0      TOR-Series       3 fld   pps        tg.1.1-48;         tg.1.1-48;
       Flood Ctrl                          fg.1.1-4           fg.1.1-4