The following example shows how to activate a port capacity license on the S- or K-Series device:
System(rw)->set license port-capacity "0001:KS-EOS-PPC:0:12345678:0:Enterprise Name:0:abcdefgh:abcdefghijklmnopqrstuvwxyz123456" slot 2
The following example shows how to display an advanced routing license information (S-Series):
System(rw)->show license License Type Location Status Key ---------------- -------- ---------- ---------------------------------------- port-capacity slot 1 active 0001:S-EOS-PPC:A:BCDEFGHI:0:Enterprise Name:0:12345678:abcdefghijklmnopqrstuvwxyz123456 port-capacity slot 2 active 0001:S-EOS-PPC:1:BCDEFGHI:0:Enterprise Name:0:12345678:abcdefghijklmnopqrstuvwxyz123456 port-capacity slot 3 active 0001:S-EOS-PPC:0:BCDEFGHI:0:Enterprise Name:0:12345678:abcdefghijklmnopqrstuvwxyz123456 l3-s130 chassis active 0001:S-EOS-L3-S130:0:abcdefg:0:Enterprise Name:0:00000000:abcdefghij+abcdefghijklmnopqrst/abcdefghijklmnopqrstuv /1234567890abcdefghijklmno/12345==
The following example shows how to display an advanced routing license information (K-Series):
System(rw)->show license License Type Location Status Key ---------------- -------- ---------- ---------------------------------------------- advanced chassis restricted 0001:K-EOS-L3:1:4abcdefg:0:Enterprise Name:0:00000000:abcdefghij+abcdefghijklmnopqrst/abcdefghijklmnopqrstuv /1234567890abcdefghijklmno/12345==
The following example shows how to clear the port capacity license on slot 2 (S-, K-Series):
System(rw)->clear license port-capacity slot 2