Tracked Object Parameters

Tracked object parameters are configured in tracked object configuration mode using the following commands:

Click to expand in new window

Configuring Tracked Object Parameters

Command Parameter Description Default Value
port Valid for port-group tracked objects only. Specifies ports to be added to the port group for tracking. None
threshold count


up


down

Valid for port-group tracked objects only. This command sets the port group threshold counts which control the up and down state of the port group tracked object.

The tracked object changes to the “up” state if the number of “up” ports is greater than or equal to the up count value. Up count value can range from 1 to 255.

The tracked object changes to the “down” state when the number of “up” ports is less than or equal to the down count value. Down count value can range from 0 to 254.

The down count must be smaller than the up count. The up count must be greater than the down count.

Up: 1

Down: 0

delay up | down This command configures the amount of time for the Tracked Object Manager to wait prior to informing client applications of a state change, either “up” or “down”. Value can range from 1 to 180 seconds. Up: 3 seconds

Down: 3 seconds

description A description of up to 127 printable characters can be configured. If a space character is entered, the description must be enclosed by double quotes (“”).

Tracked object descriptions are displayed by the show track track-name detail command.

None
inservice This command enables the tracked object. Disabled