Configuring CE Device 1
To configure CE Device 1:
- Enable CFM in global configuration mode
- Limit logging to MA maCE1
- Access MD mode for MD mdCE1 using the string-name naming convention
- Set the MD level to 5
- Enable the MD configuration
- Access MA mode for MA maCE1 using the string-name naming convention
- Set the interval between sending CCM messages to 10 seconds
- Configure the MEP list for the two down MEPs: 501 and 503
- Enable the MA configuration
- Access the MA-Comp mode for maCE1
- Set VLAN 100 as the monitored service
- Enable MA-Comp configuration for maCE1
- Access MEP configuration for MEP 501
- Set the MEP port to tg.1.1
- Set the MEP VLAN to 100
- Set the MEP direction to down (optional because down is the direction default)
- Enable the sending of CCM messages for MEP 501
- Set the remote MEP that CCM messages will be sent to 503
- Activate the MEP state machines
- Enable the MEP configuration