Configuring CE Device 1

To configure CE Device 1:

  • Enable CFM in global configuration mode
  • Limit logging to MA maCE1
  • Access MD mode for MD mdCE1 using the string-name naming convention
  • Set the MD level to 5
  • Enable the MD configuration
  • Access MA mode for MA maCE1 using the string-name naming convention
  • Set the interval between sending CCM messages to 10 seconds
  • Configure the MEP list for the two down MEPs: 501 and 503
  • Enable the MA configuration
  • Access the MA-Comp mode for maCE1
  • Set VLAN 100 as the monitored service
  • Enable MA-Comp configuration for maCE1
  • Access MEP configuration for MEP 501
  • Set the MEP port to tg.1.1
  • Set the MEP VLAN to 100
  • Set the MEP direction to down (optional because down is the direction default)
  • Enable the sending of CCM messages for MEP 501
  • Set the remote MEP that CCM messages will be sent to 503
  • Activate the MEP state machines
  • Enable the MEP configuration