show temperature

show temperature

Description

This command displays the current temperature of the power supply controllers and the switch.

On a stack, the command displays the current temperature of the switches in each slot.

Syntax Description

This command has no arguments or variables

Default

N/A.

Usage Guidelines

Depending on the software version running on your switch or your switch model, additional or different temperature information might be displayed.

Use this command to display the temperature in Celsius and the current status of the standalone switch or all switches in a stack.

Bridge Port Extenders (BPEs)

Temperature information for bridge port extenders (BPEs) does not appear in this command. Use the show vpex bpe {slot slot_num} {environment} command instead.

Example

The following is sample output from a SummitStack of 8 nodes:

Slot-3 Stack.1 # show temperature
Field Replaceable Units               Temp (C)   Status   Min  Normal  Max
--------------------------------------------------------------------------
Slot-1         :
Slot-2         : SummitX                34.50    Normal   -10    0-54  59
Slot-3         : SummitX                36.50    Normal   -10    0-66  67
Slot-4         :
Slot-5         :
Slot-6         :
Slot-7         :
Slot-8         :
Slot-3 Stack.2 #

The following is a sample output when a USB dongle temperature sensor is inserted into a supported switch:

Standalone:
5520-24W-SwitchEngine.1 # show temperature
Field Replaceable Units                                  Temp (C)   Status   Min  Normal   Max
-------------------------------------------------------  ---------  -------  ---  -------  —
Switch                : 5520-24W                           68.38    Normal     0   10-100  110
Switch                : Inlet Air                          21.50           

Stack:

Slot-1 Stack.1 # show temperature
Field Replaceable Units                                  Temp (C)   Status   Min  Normal   Max
-------------------------------------------------------  ---------  -------  ---  -------  —
Slot-1                : 5520-24W                           67.13    Normal     0   10-100  110
Slot-1                : Inlet Air                          21.50           

History

This command was first available in an ExtremeXOS 10.1.

Information about the power controller(s), a component status column, and the minimum, normal, and maximum temperature ranges of the components was added to the output in ExtremeXOS 11.0.

Support for stacking was added to output in ExtremeXOS 12.0.

USB dongle temperature sensor information was added in version 33.3.1.

Platform Availability

This command is available on all Universal switches supported in this document.