This command has no arguments or variables.
N/A.
Use this command to view the collected output of individual system commands.
# show system show switch SysName: switch-model-EXOS SysLocation: SysContact: https://www.extremenetworks.com/support/ System MAC: 00:04:96:EF:2C:00 System Type: switch-model-EXOS SysHealth check: Enabled (Normal) Recovery Mode: All System Watchdog: Enabled Trusted Delivery: UBOOT Image Verified Current Time: Tue Sep 1 14:51:40 2020 Timezone: [Auto DST Disabled] GMT Offset: 0 minutes, name is UTC. Boot Time: Tue Aug 11 18:18:57 2020 Boot Count: 105 Next Reboot: None scheduled System UpTime: 20 days 20 hours 32 minutes 43 seconds Current State: OPERATIONAL Image Selected: secondary Image Booted: secondary Primary ver: 31.1.0.398 Secondary ver: 31.1.0.485 Config Selected: primary.cfg Config Booted: primary.cfg Config Automatic: NONE (Disabled) primary.cfg Created by ExtremeXOS version 31.1.1.142 354129 bytes saved on Mon Jul 27 13:57:50 2020 LAA MAC: Locally Administered MAC Address Disabled show version Switch : 800992-01-03 2011G-00108 Rev 03 BootROM: 2.2.1.3 IMG: 31.1.0.485 Image : ExtremeXOS version 31.1.0.485 by release-manager on Thu Aug 6 07:07:23 EDT 2020 BootROM : Default 2.2.1.3 Alternate 2.2.1.3 Diagnostics : Certified Version : EXOS Linux 4.14.170, Extreme Networks FIPS Object Module 2.0.16a Build Tools Version : exos-arm64-sdk-3.0.3.1.0 show temperature Field Replaceable Units Temp (C) Status Min Normal Max ------------------------------------------------------- --------- ------- --- ------- --- Switch : switch-model-EXOS 43.00 Normal 0 10-100 110 show power PowerSupply 1 information: State : Powered On PartInfo : Internal PSU-1 1943A-33011 800592-00-15 Revision : 15 Input : 208.25 V AC Output 1 : 53.28 V, 0.82 A (12V/715W Max) Power Usage : 57.48 W Airflow Direction : Front to Back PowerSupply 2 information: State : Empty System Power Usage : 57.48 W Poll Interval : 60 s Change Threshold : N/A Change Action : N/A show fans Slot-1 FanTray-1 information: State: Operational NumFan: 2 Fan-1: Operational at 4096 RPM Fan-2: Operational at 4488 RPM Slot-1 FanTray-2 information: State: Operational NumFan: 2 Fan-1: Operational at 4028 RPM Fan-2: Operational at 4572 RPM Slot-1 FanTray-3 information: State: Operational NumFan: 2 Fan-1: Operational at 4062 RPM Fan-2: Operational at 4509 RPM show odometers Service First Recorded Field Replaceable Units Days Start Date ------------------------------------------------------- ------- -------------- Switch : switch-model-EXOS 90 May-29-2020
This command was first available in ExtremeXOS 16.1.
Solid State Storage Device SSD-120 information was added in ExtremeXOS 30.3.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, and X695 series switches.