Specifies the maximum age of a BPDU in the specified STPD.
stpd_name | Specifies an STPD name on the switch. |
seconds | Specifies the maxage time in seconds. The default is 20 seconds, and the range is 6 to 40 seconds. |
The default maximum age of a BPDU is 20 seconds.
If your STPD has the same name as another component, for example a This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, and X695 series switches., we recommend that you specify the identifying keyword as well as the name. If your STPD has a name unique only to that STPD, the keyword stpd is optional.
You should not configure any STP parameters unless you have considerable knowledge and experience with STP. The default STP parameters are adequate for most networks.
In an MSTP environment, configure the maximum age of a BPDU only on the CIST, not on the MSTIs.
The range for the seconds parameter is 6 through 40 seconds.
Note that the time must be greater than, or equal to 2 * (Hello Time + 1) and less than, or equal to 2 * (Forward Delay –1).
The following command sets the maximum age of STPD1 to 30 seconds:
configure stpd stpd1 maxage 30
This command was first available in ExtremeXOS 10.1.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, and X695 series switches.