configure erps timer hold-off

configure {erps} ring-name timer hold-off [ default | milliseconds ]

Description

Configure a hold-off timer to control when a signal fault is relayed.

Syntax Description

ring-name Alphanumeric string that identifies the ERPS ring.
default The default value, 0 milliseconds.
milliseconds The interval for the hold-off time in milliseconds, with a range of 0 to 10000.

Default

The default is 0 milliseconds.

Usage Guidelines

Use this command to configure a hold-off timer to control when a signal fault is relayed.

Example

The following command sets the hold-off timer to 1000 milliseconds for an ERPS ring named “ring1”:

configure erps ring1 timer hold-off 1000

History

This command was first available in ExtremeXOS 15.1.