unconfigure vpex mlag-id peer

unconfigure vpex mlag-id mlag_id slot

Description

In an Extended Edge Switching topology, removes the bridge port extender (BPE) slot assignment applied to an This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, and X695 series switches. identifier on the specified MLAG peer when the port connected to the BPE is physically connected to the MLAG peer switch.

Syntax Description

vpex Specifies Virtual Port Extender (VPEX).
mlag-id Specifies a unique MLAG identifier of the MLAG port attached to the bridge port extender (BPE).
mlag_id Specifies the MLAG identifier value of the MLAG port attached to the BPE. Range is 1–65,000.
slot Specifies unconfiguring the slot identifier for the attached BPE.

Default

N/A.

Usage Guidelines

The configure vpex mlag-id mlag_id peer peer_name slot slot_num command allows the MLAG peer that does not have a port in the specified MLAG to declare a Extended Edge Switching slot on that MLAG. This command enables you to unconfigure a previously declared slot on that MLAG.

Example

The following example unconfigures the slot previously declared on MLAG "11":
# unconfigure vpex mlag-id 11 slot

History

This command was first available in ExtremeXOS 22.7.

Platform Availability

This command is available on ExtremeSwitching X465 and X590 series switches.