Shows power supply, temperature, and fan status for bridge port extenders (BPE).
vpex | Specifies Virtual Port Extender (VPEX). |
bpe | Bridge port extender (BPE). |
slot | Specifies a specific port extender by slot number. |
slot_num | Specifies a specific port extender by slot number. |
environment | Specifies port extender environment information, including PSU, fan, and temperature information. |
N/A.
The following example shows environment information for all BPEs attached to the switch. In this case, there are two BPEs: one attached on port 1:45 and assigned to slot 100, and another attached on port 1:45 and assigned to slot 101:
# show vpex bpe environment BPE Environment Information Cascade Port: 1:41 Slot: 100 MAC: d8:84:66:88:98:74 Description: Floor1 Serial #: 800879-00-00 1716A042010 Main PSU: Powered On Backup PSU: Empty Fan-1: Operational at 5434 RPM Sensor-1: Operational Temp: Normal Sensor-2: Operational Temp: Normal Sensor-3: Operational Temp: Normal Sensor-4: Operational Temp: Normal Cascade Port: 1:45 Slot: 101 MAC: d8:84:66:88:97:fa Description: Floor2 Serial #: 00.00.01 1705D-10009 Main PSU: Powered On Backup PSU: Empty Fan-1: Operational at 10621 RPM Sensor-1: Operational Temp: Normal Sensor-2: Operational Temp: Normal Sensor-3: Operational Temp: Normal Sensor-4: Operational Temp: Normal
This command was first available in ExtremeXOS 22.5.
This command is available on ExtremeSwitching X465 and X590 series switches.