Specifies that a higher priority backup router does not preempt a lower priority master.
vlan_name |
Specifies the name of a VRRP This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, and X695 series switches.. |
vridval |
Specifies the VRID of a VRRP instance. To display the configured VRRP router instances, enter the show vrrp command. |
The default setting is preempt.
The preempt mode controls whether a higher priority backup router preempts a lower priority master. dont-preempt prohibits preemption. The router that owns the virtual IP address always preempts, independent of the setting of this parameter.
The following command disallows preemption:
configure vrrp vlan vlan-1 vrid 1 dont-preempt
This command was first available in ExtremeXOS 10.1.
This command is available on platforms that support the appropriate license. For complete information about software licensing, including how to obtain and upgrade your license and which licenses support the VRRP feature, see the ExtremeXOS 32.1 Feature License Requirements document.