Specifies the VLAN advertised to Fabric Attach clients for them to use as the management VLAN.
management-vlan | Specifies setting he VLAN advertised to Fabric Attach clients for them to use as the management VLAN. (Default is none.) |
vlan_id | Specifies the Management VLAN ID tag (1 and 4,094). |
vlan_name | Specifies the Management VLAN name. The VLAN must be a tagged VLAN. |
untagged | Management traffic should be sent untagged. |
none | No Fabric Attach Management VLAN is in use. |
forward | Configures whether Fabric Attach proxy switches send Management VLAN data to clients. |
on | Fabric Attach proxy switches send Management VLAN data to clients (default). |
off | Fabric Attach proxy switches do not send Management VLAN data to clients. |
Unless configured, there is no Management VLAN by default.
If not specified, the Fabric Attach proxy switches send Management VLAN data to clients.
Configuring the Fabric Attach Management VLAN is only relevant when operating as a Fabric Attach Server. It has no effect when operating as a client or proxy.
Fabric Attach Management VLAN forwarding configuration is relevant for all FA modes.
The management VLAN is advertised to Fabric Attach proxies and clients.
The specified VLAN configuration on the Fabric Attach server is restricted to only tagged VLANs.
The following example sets the Management VLAN to a VLAN named "VLAN1" and specifies tagged traffic:
# configure fabric attach management-vlan VLAN1
This command was first available in ExtremeXOS 22.5.
The option to configure whether Fabric Attach proxy switches send Management VLAN data to clients was added in ExtremeXOS 30.6.
This command is available on the ExtremeSwitching X465 and X590 series switches.