Note
This command has been replaced with the following command: configure l2vpn [vpls vpls_name | vpws vpws_name] delete service [{vlan} vlan_name | {vman} vman_name] .
This command is still supported for backward compatibility, but it will be removed from a future release, so we recommend that you start using the new command.
Deletes local VPLS service from the specified vpls_name.
vpls_name | Identifies the VPLS interface within the switch (character string). |
vlan_name | Logically binds the This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, and X695 series switches. to the specified VPLS. |
vman_name | Adds the named VMAN to the VPLS. |
N/A.
This command deletes the local VPLS service from the specified vpls_name. Specifying the vlan_name or vman_name deletes the service from the VPLS. If there are no services configured for the VPLS, all PWs within the VPLS are terminated from the switch.
The following example removes a service interface from a VPLS:
configure vpls vpls1 delete vman vman1
This command was first available in ExtremeXOS 11.6.
This command is available only on the platforms that support MPLS as described in the ExtremeXOS 32.1 Feature License Requirements document.