sflow source-interface

Specifies to pick the IPv4 or IPv6 address of either the Ethernet, Virtual Ethernet (ve), management, or loopback interface as the source of sFlow packets.

Syntax

sflow source-interface { ethernet slot/port | loopback loopback_num | management mgmt-id | ve ve_interface }
no sflow source-interface

Command Default

By default, sFlow uses the management port IP address as the source IP.

Parameters

ethernet slot/port
Specifies an Ethernet slot and port. The only supported slot value on the fixed form factor SLX devices is 0.
loopback loopback_num
Specifies a loopback interface. Valid values range from 1 through 255.
management mgmt-id
Specifies the management interface. The only supported value is 0.
ve ve-interface-number
Specifies a virtual Ethernet (VE) interface. Valid values range from 1 through 4096.

Modes

Global configuration mode

Usage Guidelines

The no form of the command is available after the source type has been specified.

Examples

To specify the Ethernet address as the source of sFlow packets:

device# config
device(config)# sflow source-interface ethernet 0/1

To specify the loopback interface as the source of sFlow packets:

device(config)# sflow source-interface loopback 42

To confirm the above configuration:

device(config)# do show running-config sflow
sflow enable
sflow source-interface loopback 42

To disable the above configuration and revert to the default:

device(config)# no sflow source-interface
device(config)# do show running-config sflow
sflow enable