show environment power

Displays the type and current status of the switch power supply.

Syntax

show environment power

Modes

Privileged EXEC mode

Output

The show environment power command displays the following information:

Output field Description
OK Power supply is functioning correctly.
absent Power supply is not present.
unknown Unknown power supply unit is installed.
predicting failure Power supply is present but predicting failure. Replace the power supply as soon as possible.
faulty Power supply is present but faulty (no power cable, power switch turned off, fuse blown, or other internal error).
Airflow Specifies direction of fan air flow.

Examples

The following example displays the power supply status.

device# show environment power
 
Power Supply #1 is OK
DELTA type: A V23.45 
Power Supply #2 is OK
DELTA type: A V23.45 
Power Supply #3 is absent
Power Supply #4 is absent
Power Supply #5 is absent
Power Supply #6 is absent