show cluster

Displays the MCT cluster information including client, PW client, member bridge domain, and member VLAN information.

Syntax

show cluster
show cluster client [ cluster-ID | A.B.C.D ]
show cluster client-pw
show cluster icl { brief | detail | statistics }
show cluster member { bridge-domain | vlan }

Parameters

client
Specifies the cluster ID or IP address.
cluster-ID
Specifies the cluster client ID.
A.B.C.D
Specifies the cluster IP address.
client-pw
(DNX devices only) Specifies PW client information for VPLS or VLL MCT.
icl
Specifies inter-chassis link (ICL) information.
brief
Specifies brief ICL information.
detail
Specifies detailed ICL information.
statistics
Specifies ICL statistics.
member
Specifies member bridge-domains or VLANs.
bridge-domain
Specifies cluster bridge domains.
vlan
Specifies cluster VLANs.

Modes

Privileged EXEC mode

Usage Guidelines

When you delete an IP router ID that is used as the neighbor ID and IP address on an MCT peer, the show cluster command on the MCT peer devices displays inconsistent cluster states.

Output

The show cluster command displays the following information:

Output field Description
Cluster Name of the cluster
Cluster State Whether the cluster is deployed or undeployed
Client Isolation Mode Client-isolation mode configuration: Strict or Loose.
DF Hold Time Designated-forwarder hold timer value.
Configured Member Vlan Range Configured VLANs as members to the MCT cluster.
Active Member Vlan Range Active member VLANs.
Configured Member BD Range Configured bridge domains as members to the MCT cluster.
Active Member BD Range Active member bridge domains.
No. of Peers Number of cluster peers.
No. of Clients Number of cluster clients.
Peer Info Peer information
Peer IP Configured IP address for the MCT cluster peer.
State Whether the peer state is UP or DOWN.
Peer Interface Configured peer interface slot and port.
ICL Tunnel Type State of the MPLS tunnel to reach the MCT peer.
PW client Info PW client information. The SLX 9150 and SLX 9250 devices do not support the PW client.
ESI Configured Ethernet Segment ID (ESI) value.
Deploy Whether the PW client is deployed (TRUE or FALSE).
State Whether the client state is UP or DOWN.
Client Info Cluster client information
Name Configured client name.
ID Configured client ID.
ESI Configured 9-byte Ethernet Segment ID (ESI) value or 10-byte auto-generated ESI.
Interface Configured interface assigned to the client.
Local/Remote State Local and remote state of the client; Up or Down, Deployed (Dep) or Undeployed (UnDep).
On the SLX 9540 and SLX 9640 devices, the client-pw option with the show cluster command displays the following information:
Output field Description
Client Client type as Client-pw.
Client ID Internally-generated PW client ID.
Deployed or Undeployed Whether the PW client is deployed or undeployed
State Whether the PW client state is Up or Down.
Bridge-domains Configured bridge domains IDs.
Elected DF for Bridge-domains Bridge domain ID elected as the designated forwarder.

Examples

On the SLX 9540 and SLX 9640 devices, the following example shows the information of the cluster on the SLX-OS device.

device# show cluster 1

Cluster MCT1 1
==============
Cluster State: Deploy
Client Isolation Mode: Loose
DF Hold Time: 3
Configured Member Vlan Range: 2, 4-7
Active Member Vlan Range: 2, 4-7
Cluster Control Vlan: 4090
Configured Member BD Range:
Active Member BD Range:
No. of Peers: 1
No. of Clients: 2

 Peer Info:
 ----------
 Peer IP: 10.10.10.20, State: Up 
 Peer Interface: Not Configured
 ICL Tunnel Type: MPLS, State: Up 

 Client Info:
 ------------
 Name     Id   ESI	                   Interface       Local/Remote State
 c1       1    0:11:22:33:80:0:0:0:0:0      Ethernet 0/3    Up/Up
 c1       2    0:11:22:33:81:0:0:0:0:0      Port-channel 20 Up/Up
On the SLX 9540 and SLX 9640 devices, the following example shows the PW client information.
device#show cluster 1 client-pw
Client Info:
============
Client: Client-pw, client-id: 34816, Deployed, State: Up
Interface: PW
Bridge-domains: 8100-8101
Elected DF for Bridge-domains:
8100
The following example shows the member bridge-domain information.
device# show cluster member bridge-domain
 BD-ID     Mcast-label(Lo/Re)    Unicast-label(Lo/Re)    Forwarding state
-------    -----------------     -------------------     ----------------
  1000       822248/ -1                  805864/ 0                  Down         
  1001       822249/ -1                  805865/ 0                  Down