show chassis

Displays the status for components in the device.

Syntax

show chassis [ virtual-ip ]

Parameters

virtual-ip
Displays the virtual IP address and status.

Modes

Privileged EXEC mode

Usage Guidelines

This command is executed on the local switch and is supported only on the local switch. The output of this command depends on the platforms on which it is executed.

Pagination is not supported with this command. Use the "more" parameter to display the output one page at a time.

Supply power values are positive; consumer power values are negative.

Examples

The following example displays chassis information on an SLX 9540.

device# show chassis 
Chassis Name:BR-SLX9540
switchType: 4000

POWER SUPPLY  Unit: 1
Factory Part Num:      
Factory Serial Num:    
Time Awake:            0 days

POWER SUPPLY  Unit: 2
Factory Part Num:      
Factory Serial Num:    
Time Awake:            0 days

FAN  Unit: 1
Time Awake:            0 days

FAN  Unit: 2
Time Awake:            0 days

FAN  Unit: 3
Time Awake:            0 days

FAN  Unit: 5
Time Awake:            0 days

CHASSIS/WWN  Unit: 1
Power Consume Factor: 0
Factory Part Num:      40-1001198-03
Factory Serial Num:    FBK0319M00J
Manufacture:           Day:  0  Month:  0  Year: 2000
Update:                Day:  1  Month:  2  Year: 2018
Time Alive:            646 days
Time Awake:            0 days
Rework: 0
Serial Num:   0
Rework: 0

The following example displays results of the virtual-ip option.

device# show chassis virtual-ip 