Configure an IS-IS Manual Area
Use the following procedure to configure an IS-IS manual area.
Procedure
- In the navigation pane, expand .
- Select IS-IS.
- Select the Manual Area tab.
- Select Insert.
- In the AreaAddr field, type the Area Address.
- Select Insert.
Manual Area or Manual Area Remote Field Descriptions
Use the data in the following table to use the Manual Area or Manual Area Remote tab.
Name |
Description |
---|---|
AreaAddr |
Specifies the IS-IS manual area. Valid value is 1-13 bytes in the format <xx.xxxx.xxxx...xxxx>. Only one manual area is supported. Use the same manual area across the entire SPBM cloud. For IS-IS to operate, you must configure at least one manual area. |