View DDI Temperature Information
About this task
This command displays information for DDI transceivers.
Note
Transceiver support differs across hardware platforms. For information about supported parts, see Extreme Optics website.
Procedure
Example
Switch:1#show pluggable-optical-modules temperature ================================================================================ Pluggable Optical Module Temperature(C) ================================================================================ PORT LOW_ALARM LOW_WARN ACTUAL HIGH_WARN HIGH_ALARM THRESHOLD NUM THRESHOLD THRESHOLD VALUE THRESHOLD THRESHOLD STATUS -------------------------------------------------------------------------------- 1/2 7.0 1.1250 65.2539 0.0 3.0156 Low Alarm 1/3 7.0 1.1250 65.2539 0.0 3.0156 Low Alarm 1/9 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm 1/15 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm 2/1 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm 2/2 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm 2/3 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm
Variable Definitions
Use the data in the following table to use the show pluggable-optical-modules temperature command.
Variable |
Value |
---|---|
{slot/port[/sub-port][-slot/port[/sub-port]][,...]} |
Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port. |