5420 Series

In addition to the regular fixed ports, all 5420 Series switches have two SFP-DD Universal Ethernet ports that are reserved for advanced features (factory default). You can also use these ports as regular ports if you do not require the advanced features. For more information about using the advanced-feature-bandwidth-reservation boot flag to configure the functionality of these ports, see Advanced Feature Bandwidth Reservation.

When advanced features are disabled on these SFP-DD Universal Ethernet ports, they can function as regular Ethernet ports, supporting data rates of either 10Gb using SFP+ optics or 20Gb using SFP-DD optics. 5420M switch models support two 10Gb channels on each SFP-DD port. 5420F switch models support one 10Gb channel on each SFP-DD port when the ports are used as Ethernet ports.

Note

Note

25 SFP28 direct attach cables (DAC) handling in SFP28 and SFP+ ports can be used for 25Gb and 10Gb by setting speed or Custom Auto-Negotiation Advertisement (CANA) at both ends.

Front panel ports 1/1-1/28, 1/29/1, 1/29/2, 1/30/1, and 1/30/2 can be used for traffic on the following switches:

Front panel ports 1/1-1/52, 1/53/2, 1/53/1, 1/53/2, 1/54/1, and 1/54/2 can be used for traffic on the following switches:

On the following switches, you can create two 10Gb channels on each SFP-DD port:

5420F-8W-16P-4XE

The following diagram illustrates the components of the front panel of the 5420F-8W-16P-4XE switch.

Click to expand in new window
5420F-8W-16P-4XE Front Panel
Front view of 5420F-8W-16P-4XE

The front panel of the 5420F-8W-16P-4XE switch includes:

  1. 8 10/100/1000BASE-T full-duplex (FDX), half-duplex (HDX) 802.3bt Type 4 PoEMACsec-capable ports, 16 1000BASE-T FDX/HDX Type 2 PoE+ MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK, and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10 Gbps SFP+ ports

The back panel (not shown) includes two fixed fan modules, an AC power inlet connector, a power supply slot, and a grounding lug.

5420F-24P-4XE

The following diagram illustrates the components of the front panel of the 5420F-24P-4XE switch.

Click to expand in new window
5420F-24P-4XE Front Panel
Front panel of the 5420F-24P-4XE

The front panel of the 5420F-24P-4XE switch includes:

  1. 24 10/100/1000BASE-T FDX/HDX 802.3bt Type 2 PoE+ MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10 Gbps SFP+ ports

The back panel (not shown) includes 2 fixed fan modules, an AC power inlet connector, a power supply slot, and a grounding lug.

5420F-24S-4XE

The following diagram illustrates the components of the front panel of the 5420F-24S-4XE switch.

Click to expand in new window
5420F-24S-4XE Front Panel
Front Panel of 5420F-24S-4XE switch

The front panel of the 5420F-24S-4XE switch includes:

  1. 24 1000BASE-X SFP MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 10 Gbps SFP+ ports

The back panel (not shown) includes 2 fixed fan modules, an AC power inlet connector, a power supply slot, and a grounding lug.

5420F-24T-4XE

The following diagram illustrates the components of the front panel of the 5420F-24T-4XE switch.

Click to expand in new window
5420F-24T-4XE Front Panel
Front Panel of 5420F-24T-4XE switch

The front panel of the 5420F-24T-4XE switch includes:

  1. 24 10/100/1000BASE-T FDX/HDX MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10 Gbps SFP+ ports

The back panel (not shown) includes 2 fixed fan modules, an AC power inlet connector, a power supply slot, and a grounding lug.

5420F-16MW-32P-4XE

The following diagram illustrates the components of the front panel of the 5420F-16MW-32P-4XE switch.

Click to expand in new window
5420F-16MW-32P-4XE Front Panel
Front pane of 5420F-16MW-32P-4XE switch

The front panel of the 5420F-16MW-32P-4XE switch includes:

  1. 16 100Mb/1GB/2.5GB 802.3bt Type 4 PoE ports.

  2. 32 10/100/1000BASE-T FDX/HDX Type 2 PoE+ MACsec-capable ports.

  3. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  4. 1 Micro-B USB console port

  5. 1 RJ-45 out of band (OOB) management port

  6. 1 RJ-45 serial console port

  7. 2 Type-A USB ports

  8. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  9. 4 1/10 Gbps SFP+ ports

The back panel (not shown) includes three fixed fan modules, a power supply slot, an AC power inlet connector, and a grounding lug.

5420F-16W-32P-4XE

The following diagram illustrates the components of the front panel of the 5420F-16W-32P-4XE switch.

Click to expand in new window
5420F-16W-32P-4XE Front Panel
Front panel of 5420F-16W-32P-4XE5420F-16W-32P-4XE switch

The front panel of the 5420F-16W-32P-4XE switch includes:

  1. 16 10/100/1000BASE-T FDX/HDX 802.3bt Type 4 PoE MACsec-capable ports.

  2. 32 10/100/1000BASE-T FDX/HDX Type 2 PoE+ MACsec-capable ports.

  3. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  4. 1 Micro-B USB console port

  5. 1 RJ-45 out of band (OOB) management port

  6. 1 RJ-45 serial console port

  7. 2 Type-A USB ports

  8. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  9. 4 1/10 Gbps SFP+ ports

The back panel (not shown) includes three fixed fan modules, a power supply slot, an AC power inlet connector, and a grounding lug.

5420F-48P-4XE

The following diagram illustrates the components of the front panel of the 5420F-48P-4XE switch.

Click to expand in new window
5420F-48P-4XE Front Panel
Front panel of 5420F-48P-4XE switch

The front panel of the 5420F-48P-4XE switch includes:

  1. 48 10/100/1000BASE-T FDX/HDX Type 2 PoE+ MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10 Gbps SFP+ ports

The back panel (not shown) includes three fixed fan modules, a power supply slot, an AC power inlet connector, and a grounding lug.

5420F-48P-4XL

The following diagram illustrates the components of the front panel of the 5420F-48P-4XL switch.

Click to expand in new window
5420F-48P-4XL Front Panel
Front Panel of 5420F-48P-4XL switch

The front panel of the 5420F-48P-4XL switch includes:

  1. 48 10/100/1000BASE-T FDX/HDX Type 2 PoE+ MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10 Gbps LRM/MACsec-capable SFP+ ports

The back panel (not shown) includes three fixed fan modules, a power supply slot, an AC power inlet connector, and a grounding lug.

5420F-48T-4XE

The following diagram illustrates the components of the front panel of the 5420F-48T-4XE switch.

Click to expand in new window
5420F-48T-4XE Front Panel
Front panel of 5420F-48T-4XE switch

The front panel of the 5420F-48T-4XE switch includes:

  1. 48 10/100/1000BASE-T FDX/HDX MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10 Gbps SFP+ ports

The back panel (not shown) includes two fixed fan modules, a power supply slot, an AC power inlet connector, and a grounding lug.

5420M-24T-4YE

The following diagram illustrates the components of the front panel of the 5420M-24T-4YE switch.

Click to expand in new window
5420M-24T-4YE Front Panel
Front panel of 5420M-24T-4YE switch

The front panel of the 5420M-24T-4YE switch includes:

  1. 24 10/100/1000BASE-T FDX/HDX Type 2 MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10/25 Gbps SFP28 ports

The back panel (not shown) includes a removable fan module, two power supply slots, and a grounding lug.

5420M-24W-4YE

The following diagram illustrates the components of the front panel of the 5420M-24W-4YE switch.

Click to expand in new window
5420M-24W-4YE Front Panel
Front panel of 5420M-24W-4YE switch

The front panel of the 5420M-24W-4YE switch includes:

  1. 24 10/100/1000BASE-T FDX/HDX 802.3bt Type 4 PoE MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10/25 Gbps SFP28 ports

The back panel (not shown) includes a removable fan module, two power supply slots, and a grounding lug.

5420M-16MW-32P-4YE

The following diagram illustrates the components of the front panel of the 5420M-16MW-32P-4YE switch.

Click to expand in new window
5420M-16MW-32P-4YE Front Panel
Front panel of 5420M-16MW-32P-4YE switch

The front panel of the 5420M-16MW-32P-4YE switch includes:

  1. 16 100Mb/1Gb/2/5Gb 802.3bt Type 4 PoE ports.

  2. 32 10/100/1000BASE-T FDX/HDX Type 2 PoE+ MACsec-capable ports.

  3. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  4. 1 Micro-B USB console port

  5. 1 RJ-45 out of band (OOB) management port

  6. 1 RJ-45 serial console port

  7. 2 Type-A USB ports

  8. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  9. 4 1/10/25 Gbps SFP28 ports

The back panel (not shown) includes a removable fan module, two power supply slots, and a grounding lug.

5420M-48T-4YE

The following diagram illustrates the components of the front panel of the 5420M-48T-4YE switch.

Click to expand in new window
5420M-48T-4YE Front Panel
Front panel of 5420M-48T-4YE5420M-48T-4YE switch

The front panel of the 5420M-48T-4YE switch includes:

  1. 48 10/100/1000BASE-T FDX/HDX MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10/25 Gbps SFP28 ports

The back panel (not shown) includes a removable fan module, two power supply slots, and a grounding lug.

5420M-48W-4YE

The following diagram illustrates the components of the front panel of the 5420M-48W-4YE switch.

Click to expand in new window
5420M-48W-4YE Front Panel
Front panel view of the 5420M-48W-4YE switch

The front panel of the 5420M-48W-4YE switch includes:

  1. 48 10/100/1000BASE-T FDX/HDX 802.3bt Type 4 PoE ports MACsec-capable ports.

  2. Mode button for port LED control. Port LED mode indicators (SYS, SPD, STK and BT). Switch LEDs for system power (P1, P2), fan (FAN), and System Locator LED (LOC).

    Note

    Note

    The software only supports SYS and SPD LED mode indicators. STK and BT LED indicators remain off.
  3. 1 Micro-B USB console port

  4. 1 RJ-45 out of band (OOB) management port

  5. 1 RJ-45 serial console port

  6. 2 Type-A USB ports

  7. 2 SFP-DD Universal Ethernet ports (labeled U1 and U2)

  8. 4 1/10/25 Gbps SFP28 ports

The back panel (not shown) includes a removable fan module, two power supply slots, and a grounding lug.