View DDI Voltage Information
About this task
This command displays information for DDI transceivers.
Procedure
Example
Switch:1#show pluggable-optical-modules voltage ================================================================================ Pluggable Optical Module Voltage(V) ================================================================================ PORT LOW_ALARM LOW_WARN ACTUAL HIGH_WARN HIGH_ALARM THRESHOLD NUM THRESHOLD THRESHOLD VALUE THRESHOLD THRESHOLD STATUS -------------------------------------------------------------------------------- 1/2 0.1281 0.0 1.2596 0.5376 1.6396 Normal 1/3 0.0001 0.0 1.2596 0.3072 1.6396 Normal 1/9 0.0006 0.0 1.2596 2.6368 0.0 Normal 1/15 0.0006 0.0 1.2596 2.6368 0.0 Normal 2/1 0.0006 0.0 1.2596 2.6368 0.0 Normal 2/2 0.0006 0.0 1.2596 2.6368 0.0 Normal 2/3 0.0006 0.0 1.2596 2.6368 0.0 Normal
Variable Definitions
Use the data in the following table to use the show pluggable-optical-modules voltage command.
Variable |
Value |
---|---|
{slot/port[/sub-port][-slot/port[/sub-port]][,...]} |
Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port. |