show bfd vlan counters

show bfd vlan {vlan_name} counters

Description

Displays BFD counters on a specified This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, X870, 5320, 5420, 5520 series switches..

Syntax Description

vlan_name

Specifies the VLAN name.

Default

N/A.

Usage Guidelines

Use this command to display counter readings for a specified VLAN.

This command is not supported by hardware-assisted BFD.

Example

The following command displays the counter readings for the VLAN vlan10:

# show bfd vlan vlan10 counters

Following is sample output from this command:

VLAN                 								: vlan10
Valid Rx Pkt             : 144
Total Tx Pkt             : 144
Auth Type Fails          : 0
Authentication Fails     : 0
Discarded Pkt            : 0
Rx session Not Found     : 6
Note

Note

The Discarded Pkt counter is incremented when the neighbor state indicated in the BFD packet is not one of the expected/allowed states. The Rx session Not Found counter is incremented when the BFD session corresponding to the received BFD packet is not found.