Displays BFD counters on a specified This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, X870, 5320, 5420, 5520 series switches..
vlan_name |
Specifies the VLAN name. |
N/A.
Use this command to display counter readings for a specified VLAN.
This command is not supported by hardware-assisted BFD.
The following command displays the counter readings for the VLAN vlan10:
# show bfd vlan vlan10 counters
Following is sample output from this command:
VLAN : vlan10 Valid Rx Pkt : 144 Total Tx Pkt : 144 Auth Type Fails : 0 Authentication Fails : 0 Discarded Pkt : 0 Rx session Not Found : 6
Note
The Discarded Pkt counter is incremented when the neighbor state indicated in the BFD packet is not one of the expected/allowed states. The Rx session Not Found counter is incremented when the BFD session corresponding to the received BFD packet is not found.
This command was first available in ExtremeXOS 12.4.
This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, , X695, X870, 5420, 5520 series switches.