Deletes a maintenance end point (MEP) or maintenance intermediate point (MIP) from that MA.
domain_name |
Enter the domain associated with the MA you are configuring. |
association_name |
IEEE 802.1ag or ITU-T Y.1731 association name |
port_list |
Specifies the port number(s). |
up |
Specifies that an UP MEP is to be deleted. |
down |
Specifies that a DOWN MEP is to be deleted. |
N/A.
Use this command to delete an MEP or MIP.
If the VPLS option is chosen then the CFM deletes all the VPLS-based MIPs.
Use the show cfm command to verify your configuration.
The following command deletes port 5:12 as an MIP on the test association in the brazil domain:
configure cfm domain brazil association test ports 5:12 delete intermediate-point
The following command deletes an UP MEP on port 5:10 on the test association in the brazil domain:
configure cfm domain brazil association test ports 5:10 delete end-point up
This command was first available in ExtremeXOS 11.4.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, X870, 5320, 5420, and 5520 series switches.