show netlogin authentication failure vlan

show netlogin authentication failure [ {vlan} vlan_name | vlan vlan_list]

Description

Displays the authentication failure This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, X870, 5320, 5420, 5520 series switches. related configuration details.

Syntax Description

vlan_name Specifies the name of a failure VLAN.
vlan_list Specifies the failure VLAN list of IDs.

Default

N/A.

Usage Guidelines

Use this command to display configuration details for the authentication failure VLAN.

Example

The following is sample output from this command:

# show netlogin authentication failure vlan

------------------------------------------------------------------------------
Authentication Service unavailable Vlan																	port                     Status
------------------------------------------------------------------------------
corp 																	1:2                      Disabled

History

This command was first available in ExtremeXOS 12.1.

The vlan_list variable was added in ExtremeXOS 16.1.

Platform Availability