configure ports link-scan interval

configure ports link-scan interval [ milliseconds | default ] { slot [ slot | all ] }

Description

Configures the link-scan interval. The configure command allows the user to set the interval in a range between the default for the platform and 500 ms. A higher interval can free up CPU cycles when fast link detection is not a requirement.

Syntax Description

ports Ports.
link-scan Configure link scan attributes for polling port status.
interval Configure amount of time between polling port status
milliseconds Interval in milliseconds. Range is 50 to 500 for most platforms. The minimum interval depends on the default for the platform."; type="int"; range="[50,500]
default Default interval (50 ms for most platforms).
slot Slot number (default all slots)"; capability="slot_available"
all All slots.

Default

50 ms.

Usage Guidelines

Use this command to configure the link-scan interval.

Example

# sh ports link-scan
Slot   Interval (ms)
-----  ---------------       
    1     50 (default)     
    2    300
    3     50 (default)   
    4     50 (default)   
    5   
    6
    7   
    8    200

History

This command was first available in ExtremeXOS 15.4.

Platform Availability

This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, X870, 5320, 5420, and 5520 series switches.