Creates a maintenance association (MA) related to a specified maintenance domain (MD). This command supports the 2-octet integer MA format.
domain_name |
Specifies the domain you want to associate with this MA. |
int |
Enter an integer to name the MA. The range is 0 to 65535. |
vlan_name |
Specifies the This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, X870, 5320, 5420, 5520 series switches. you want to assign to this MA. Each MA contains only one VLAN, VMAN, BVLAN or SVLAN. |
vman_name |
Specifies the VMAN you want to assign to this MA. |
N/A.
All ports configured on the specified VLAN are now CFM ports in the specified MA.
You add the MA, or association, to the domain, and the MA uses the MD level assigned to the domain. Each MA can belong to only one domain, but several MAs can belong to a given domain. The MA is unique within a given domain.
The following command creates a 2-octet integer MA (350) that associates the domain brazil and the VLAN admin:
configure cfm domain brazil add association integer 350 vlan admin
This command was first available in ExtremeXOS 11.4.
The SVLAN option was added in ExtremeXOS 12.4.
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, X870, 5320, 5420, and 5520 series switches.