configure inline-power usage-threshold
configure inline-power usage-threshold threshold
Description
Sets the inline power usage SNMP event
threshold.
Syntax Description
threshold
|
Specifies the percentage of
budgeted power used on any This command
is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X620, 5320, 5420,
5520 series switches. switch
that causes the system to send an SNMP event and create a log
message. The range 1 to 99; the default value is 70. |
Usage Guidelines
This command sets the threshold for generating an SNMP event and an EMS
message. On a SummitStack, this threshold is when the measured power for a PoE
module compared to the budgeted power for that slot exceeds a certain value. On
stand-alone switches, this threshold applies to the total power available to the
entire switch. The configured threshold value initiates the event and message once
that percentage of the budgeted power is being used.
The
system generates an additional SNMP event and EMS message once the
power usage falls below the threshold again; once the condition
clears.
Example
The following command
sets the inline power usage alarm threshold at 75%:
configure inline-power usage-threshold 75
History
This command was first available in ExtremeXOS 11.1.
Platform Availability
This command is available on:
- ExtremeSwitching
X450-G2-24p-GE4—ExtremeXOS 16.1 and
later.
- ExtremeSwitching
X450-G2-48p-GE4—ExtremeXOS 16.1 and
later.
- ExtremeSwitching
X450-G2-24p-10GE4—ExtremeXOS 16.1 and
later.
- ExtremeSwitching
X450-G2-48p-10GE4—ExtremeXOS 16.1 and
later.
- ExtremeSwitching
X460-G2-24p-10GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-48p-10GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-24p-GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-48p-GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-16mp-32p-10GE4—ExtremeXOS 15.6 and
later.
- ExtremeSwitching
X460-G2-24p-24hp-10GE4—ExtremeXOS 22.2 and
later.
- ExtremeSwitching
X440-G2-48p-10GE4—ExtremeXOS 21.1 and
later.
- ExtremeSwitching
X440-G2-24p-10GE4—ExtremeXOS 21.1 and later.
- ExtremeSwitching
X440-G2-12p-10GE4—ExtremeXOS 21.1 and
later.
- ExtremeSwitching X465-48P—ExtremeXOS 30.2 and later.
- ExtremeSwitching
X435-8P-4S—ExtremeXOS 30.5 and
later.
- ExtremeSwitching
X435-24P-4S—ExtremeXOS 30.5 and
later.
- ExtremeSwitching
X435-8P-2T-W—ExtremeXOS 30.5 and
later.
- ExtremeSwitching
5420F-8W-16P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-24P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-16MW-32P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-16W-32P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-48P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420F-48P-4XL—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5420M-16MW-32P-4YE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching
5320-48P-8XE—ExtremeXOS 31.6 and
later.
- ExtremeSwitching
5320-24P-8XE—ExtremeXOS 31.6 and
later.
- ExtremeSwitching
5320-16P-4XE—ExtremeXOS 31.7 and
later.
- ExtremeSwitching
5320-16P-4XE-DC—ExtremeXOS 31.7 and
later.
- ExtremeSwitching
X620-16p—ExtremeXOS 22.2 and
later.
- ExtremeSwitching X465-24MU-24W—ExtremeXOS 30.2 and later.
- ExtremeSwitching X465-48W—ExtremeXOS 30.2 and later.
- ExtremeSwitching X465-24MU—ExtremeXOS 30.2 and later.
- ExtremeSwitching X465-24W—ExtremeXOS 30.2 and later.
- ExtremeSwitching
X465i-48W—ExtremeXOS 30.5 and later.
- ExtremeSwitching
5520-24W—ExtremeXOS 31.1 and later.
- ExtremeSwitching
5520-48W—ExtremeXOS 31.1 and later.
- ExtremeSwitching
5520-12MW-36W—ExtremeXOS 31.1 and later.
- ExtremeSwitching
5420F-8W-16P-4XE—ExtremeXOS 31.3 and
later.
- ExtremeSwitching 5420F-16MW-32P-4XE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420F-16W-32P-4XE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420M-24W-4YE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420M-16MW-32P-4YE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420M-48W-4YE—ExtremeXOS 31.3 and later.