Shows the IEEE Forward Error Correction (FEC) Clause 74 or 91 status of the port(s).
port_list | List of ports to show FEC modes status on. |
forward-error-correction | Specifies port FEC mode status. |
refresh | Specifies a continuous refresh of output. |
no-refresh | Specifies a static snapshot of data. |
port-number | Displays port number instead of display string. |
N/A.
The following example shows the FEC status for port 1:
show port 1 forward-error-correctionPort Forward-Error-Correction Status Monitor Port Link Forward-Error-Correction State State Clause ================================================================================ 1 R NA CL74 ================================================================================ Link State: A-Active, R-Ready, NP-Port Not Present L-Loopback Forward-Error-Correction State: E-Enabled, D-Disabled, NA-Not Available Clause: CL74-(Clause 74), CL91-(Clause 91), Unknown
This command was first available in ExtremeXOS 22.3.
This command is available on the ExtremeSwitching X670-G2, X465, X590, X690, X695, X870, 5320, 5420, and 5520 series switches.