configure inline-power detection ports

configure inline-power detection [802.3af-only | legacy-and-802.3af [4-point | 2-point] | bypass] ports port_list

Description

This command configures This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X620, 5320, 5420, 5520 series switches. device detection mode for Extreme Networks PoE devices and SummitStack. ExtremeSwitching platforms support per-port basis configuration.

Syntax Description

802.3af-only IEEE 802.3af detection only.
legacy-and-802.3af Capacitive and IEEE 802.3aqf detection.
4-point Selects 4-point detection (default).
2-point Selects 2-point detection (for extended detection signature range).
bypass No detection phase.
port_list Port list separated by a comma or - .

Default

Default is 4-point detection.

Usage Guidelines

None.

Example

# configure inline-power detection ports 1-2

History

This command was first available in ExtremeXOS 16.1.

4-point and 2-point detection options were added in ExtremeXOS 22.5.

Platform Availability

This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X620, 5320, 5420, 5520 series switches.