configure vpex mlag-id peer

configure vpex mlag-id mlag_id peer peer_name slot slot_num

Description

In an Extended Edge Switching topology, allows the bridge port extender (BPE) slot assignment to be applied to an This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, X870, 5320, 5420, 5520 series switches. identifier on the specified MLAG peer when the port connected to the BPE is physically connected to the MLAG peer switch.

Syntax Description

vpex Specifies Virtual Port Extender (VPEX).
mlag-id Specifies setting a unique MLAG identifier of the MLAG port attached to the bridge port extender (BPE).
mlag_id Sets the MLAG identifier value of the MLAG port attached to the BPE. Range is 1–65,000.
peer Specifies naming the MLAG peer switch.
peer_name Name of the MLAG peer switch.
slot Specifies configuring the slot identifier for the attached BPE.
slot_num Specifies the BPE slot number. Range is 100–162.

Default

N/A

Usage Guidelines

An Extended Edge Switching topology allows the BPE slot assignment to be applied to an MLAG identifier on the specified MLAG peer when the port connected to the BPE is physically connected to the MLAG peer switch.

The same Extended Edge Switching slot number must have been declared on the MLAG peer that has a port in the MLAG. On the peer with the MLAG port, either this form of the command can be used, or the traditional form where a controlling bridge port is related to a slot number.

Example

The following example for MLAG peer switch "cb2" declares slot 100 on MLAG "11":
# configure vpex mlag-id 11 peer cb2 slot 100

History

This command was first available in ExtremeXOS 22.7.

Platform Availability

This command is available on the ExtremeSwitching X670-G2 , X465 , X690, X590, 5420, 5520 series switches.