iot-ibeacon-scan-interval

Use the iot-ibeacon-scan-interval command to determine how long to wait between scans. The iot-ibeacon-scan-interval command is accessible from within the ap:<serial> context of the CLI.

Syntax

iot-ibeacon-scan-interval <100-10240>

Parameters

<100-10240 Configures the interval between successive beacon scans initiated by the AP. Valid values are: Min (100 ms) and Max (10240 ms). The default value is Min (100 ms).

Usage

The IoT functionality is supported on the AP3912i, AP3915, AP3916ic, and AP3917. Enable iot-admin and iot-application ibeacon-scan before issuing this command.

Example

The following example configures the ibeacon-scan-dest-port on an AP3912i:

EWC.extremenetworks.com:ap:3912000000000000#iot-ibeacon-scan-interval 200