iot-ibeacon-scan-min-rssi

Use the iot-ibeacon-scan-min-rssi command to configure the minimum signal strength required to report a beacon. The iot-ibeacon-scan-min-rssi command is accessible from within the ap:<serial> context of the CLI.

Syntax

iot-ibeacon-scan-min-rssi <-100, -10>

Parameters

<-100, -10> This is the signal strength required to include the packet in the BLE report. Valid values: -10 to -100. Default value is -100. Data from beacons with an RSSI that is less than the Min RSSI configured value is filtered out.

Usage

The IoT functionality is supported on the AP3912i, AP3915, AP3916ic, and AP3917. Enable iot-admin and iot-application ibeacon-scan before issuing this command.

Example

The following example configures the ibeacon-scan-dest-ip address on an AP3912i:

EWC.extremenetworks.com:ap:3912000000000000# iot-ibeacon-scan-min-rssi -30