whitelist

Use the whitelist command to configure a whitelist of node sensors for the Thread Network. The whitelist command is accessible from the whitelist-iot context of the CLI.

whitelist[(add | delete)] <eui > <password>

Parameters

add Add sensor node to the whitelist.
delete Delete sensor node from the whitelist.
<eui> Extended Unique Identifier for each sensor node, determined by the sensor manufacturer.
<password> Pre-shared password. Sensor passwords are created when the sensor is commissioned, outside of ExtremeWireless. The default password is THREAD.

Usage

Configure a whitelist that defines the allowed sensor nodes and joiner sensors for the Thread Network..
Note

Note

If the whitelist is not configured, all sensors with password THREAD are accepted into the network.

Example

The following example adds a sensor node to an IoT whitelist.

EWC.extremenetworks.com:ap:whitelist-iot# whitelist add F7604280EB000000   extreme

The following example deletes a sensor node from an IoT whitelist.

EWC.extremenetworks.com:ap:whitelist-iot# whitelist delete F7604280EB000000  abcd