The card microcontroller has detected that the input voltage to the card is too low. To prevent damages to the card, it has been shut down.
Power cycle the chassis or wait around 30 minutes to see whether it will come back to normal operating range or not
Critical
Input voltage for %slot% in channel %channel% is lower than normal operating range. The card will be shut down
Name | Type |
---|---|
slot | String |
channel | uInt |