View DDI Voltage Information

About this task

This command displays information for DDI transceivers.

Procedure

  1. Enter Privileged EXEC mode:

    enable

  2. View voltages:

    show pluggable-optical-modules voltage [{slot/port[/sub-port] [-slot/port[/sub-port]] [,...]}]

Example

Switch:1#show pluggable-optical-modules voltage

================================================================================
                      Pluggable Optical Module Voltage(V)
================================================================================
PORT         LOW_ALARM LOW_WARN    ACTUAL  HIGH_WARN HIGH_ALARM THRESHOLD
NUM          THRESHOLD THRESHOLD   VALUE   THRESHOLD THRESHOLD  STATUS
--------------------------------------------------------------------------------
1/2             0.1281    0.0       1.2596    0.5376    1.6396  Normal
1/3             0.0001    0.0       1.2596    0.3072    1.6396  Normal
1/9             0.0006    0.0       1.2596    2.6368    0.0     Normal
1/15            0.0006    0.0       1.2596    2.6368    0.0     Normal
2/1             0.0006    0.0       1.2596    2.6368    0.0     Normal
2/17            0.0006    0.0       1.2596    2.6368    0.0     Normal
2/40            0.0006    0.0       1.2596    2.6368    0.0     Normal

Variable Definitions

Use the data in the following table to use the show pluggable-optical-modules voltage command.

Variable

Value

{slot/port[/sub-port][-slot/port[/sub-port]][,...]}

Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port.