Click the New Template button to add a new profile.
Define your Sensor Settings profile using the following fields are:
Field | Description |
---|---|
Primary Appliance |
Specifies the IP address of the primary appliance. |
Secondary Appliance |
Specifies the IP address of the secondary appliance. |
Sensor Admin Password |
Specifies the admin password for your Sensors. Supplying this password is mandatory. |
Sensor Monitor Password |
Specifies the monitor password for your Sensors. |
Link Speed |
Selects the link speed. Link Speed Control enables you to set the Ethernet interface to either auto-negotiate (default), or to fix the interface to 10Mbps (Full or Half duplex) or 100Mbps (Full or Half duplex). |
MTU |
Specifies the Maximum Transmission Unit. |
Enable IP Alias |
Turns on IP aliasing. |
CDP Interval with interval |
Turns on CDP and then enter an interval in seconds. |
Enable FIPS mode |
FIPS Level Encryption is disabled by default. FIPS level encryption is generally not needed.If you want to use FIPS level encryption, select the checkbox. This setting controls the https encryption level between the Sensor and the browser. When selected, the Sensor will only allow AES encryption to the browser (Sensor UI). Only browsers that support this type of encryption will be able to connect to the Sensor UI (e.g. Firefox) once this setting is configured to yes. If you are using IE, do not select this option. Communication between the Sensor and the server is not affected by this setting, and is always negotiated for AES.Note: FIPS level encryption is incompatible with Internet Explorer. |
Remote syslog to address |
Selects if you want to use a remote Syslog host. You must enter the host IP address along with the port number. |
Radio 1 (b/g) custom gain (dbi) |
Increases the signal level of radio 1 antennas by the specified value (in dBi). |
Radio 2 (a) custom gain (dbi) |
Increases the signal level of radio 2 antennas by the specified value (in dBi). |
Prevent Auto Adoption |
Prevents a sensor from being adopted by a switch. |
Once you have defined your Sensor Settings profile, click Save to save your profile or Cancel to exit without saving the profile.