Procedure

Follow these steps to plan your sensor placement:

  1. Obtain Maps/Layouts of the facility and determine the traversal plan.
  2. Start AirDefense Mobile.
  3. Turn on the target device ( could be a laptop/PDA with wireless client card). AirDefense Mobile should detect the target device.
  4. Identify the target device in the AirDefense Mobile device tree.and use your mouse to right-click on it to display a list of options.
  5. Use AirDefense Mobile Options to Lock On the channel on which the target device is discovered.
  6. Right-click select the device in the Dashboard tree; select LiveView.
  7. Focus on Signal Strength in the Decode tab in LiveView. Verify that the target device is being tracked by AirDefense Mobile.
  8. When a wireless client (station) card is being used as a target, significant peaks and valleys are observable in signal strength as the card rotates through channels probing for any intrusion. The peaks are indicative of the effective signal strength relative to AirDefense Mobile.
  9. Move the target device to the anticipated fringe where a neighboring sensor would become primary.
  10. At the fringe of coverage, signal strength should be no less than -70 dBm to assure termination ability.
  11. Move AirDefense Mobile to the anticipated location of the next sensor and use the same procedure to ensure that its anticipated coverage area is valid.

    If the above sensor placement proves adequate from a coverage and cost of placement perspective, factors observed during this analysis may be extrapolated to other locations of similar construction.