Displays the configuration of an XMLC module.
This command has no arguments or variables.
N/A.
Displays the configuration of an XMLC module.
When the detail option is chosen, all configuration data including the default is displayed. Otherwise the default would not be displayed.
When the non-persistent option is chosen, UPM non-persistent configuration data is displayed.
The following command displays the xmlc configuration:
show configuration “xmlc” detail
Following is sample output from this command:
Module xmlc configuration. # create xml-notification target test url http://10.255.42.73:9080/axis/services/eventPort configure xml-notification test queue-size 100 disable xml-notification test create xml-notification target test2 url http://10.255.42.48:9080/axis/services/eventPort configure xml-notification test2 queue-size 100 enable xml-notification test2 create xml-notification target epicenter-target url http://10.255.42.48:8080/xos/webservice configure xml-notification target epicenter-target user admin encrypted-auth YWRtaW46ZXBpY2VudGVy configure xml-notification epicenter-target queue-size 100 enable xml-notification epicenter-target configure xml-notification target test add idMgr configure xml-notification target test2 add idMgr configure xml-notification target epicenter-target add idMgr
This command was first available in ExtremeXOS 12.4.
This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X590, X620, X690, X870 series switches.